Friday, January 29, 2016

New Yokomo Charger in stock now



[SPECIAL FEATURES]
Battery Charge/Discharge Profiles
YZ-114PLUS can store up to 10 profiles for either charging or discharging in memory.

Terminal Voltage Control (TVC)
Expert users can set the end voltage for the charge process.

Internal Lithium Battery Balancer
YZ-114PLUS comes equipped with an individual-cell voltage balancer. Using an external balancer
for balance charging is not necessary.

Support for Balance Discharging
YZ-114PLUS can monitor and balance the voltage of each cell individually during the discharging
process. A safety feature will automatically stop the discharge process if any of the cells exhibits an abnormal voltage.

Support for Multiple Types of Lithium Batteries
YZ-114PLUS supports various lithium batteries including LiPo, LiIon, and LiFe.

Standard Equipped with LiHV Mode
YZ-114PLUS supports "LiHV" batteries; the new generation of LiPo batteries which have an end
charge voltage of 4.35 V.

Fast Charge and Storage Charge Modes for Lithium Batteries
YZ-114PLUS comes equipped with a Fast Charge mode to reduce charging times for batteries which
support fast charging. In addition, a Storage mode is available to adjust the final voltage of the battery to
an optimal level to extend the useful life of the battery while being stored.

Re-peak Mode for NiMH and NiCd Batteries
In re-peak mode, the charge will perform a peak charge on the battery 1 to 3 times in a row automatically.
This mode can be used to ensure that a battery will be fully charged.

Adjustable Delta-peak Sensitivity for NiMH and NiCd Batteries
YZ-114PLUS contains an automatic charging termination feature based on the delta-peak voltage detection principle.
When the battery's voltage exceeds the user adjustable threshold, the charging process will be automatically stopped.

Cycling Charge and Discharge Processes
YZ-114PLUS is equipped with automatic cyclic charge and discharge mode which can be performed 1 to 5 times in a row.
This process can be performed to refresh and balance the battery in order to stimulate its activity.

Automatic Charging Current Limit
With YZ-114PLUS, it is possible to set the maximum charging current for NiMH and NiCd batteries. This is useful for
charging NiMH batteries with low internal resistance and capacity while using the "AUTO" charging mode.

LiPo Battery Meter
YZ-114PLUS contains a battery meter that can be used to check the battery's total voltage, along with the highest and
lowest voltage along with the voltage of each of the individual cells.

Battery Internal Resistance Meter
YZ-114PLUS contains a battery internal resistance meter that can be used to check the battery's total internal resistance,
along with the internal resistance of each of the cells.

Charge Capacity Limit
An user-adjustable charge capacity limit can be set to automatically terminate the charge process when the set charge
capacity is reached.

Temperature Limit
Batteries warm up while charging and discharging. By using this feature, if the battery heats up to a set temperature
the process will be stopped. Note: Optional temperature sensor (Part No. YZ-114P-2) is required to use this feature.

Processing Time Limit
Using this feature, when the charge or discharge process takes longer than the set time, the process will be
automatically stopped.

 Specifications
Input Power
AC
100240 V (5060 Hz)
DC
1118 V
Batteries
LiPo/LiIon/LiFe/LiHV
16 cells
NiMH/NiCd
115 cells
Pb
110 P (2~24 V)
Charge Current
LiPo/LiIon/LiFe/LiHV
0.11 A
1.16 A
NiMH/NiCd
Pb
Discharge Current
LiPo/LiIon/LiFe/LiHV
0.12 A
NiMH/NiCd
Pb
Balance Current
LiPo/LiIon/LiFe/LiHV
Max. 200 mA / cell
Trickle Current
NiMH/NiCd
50mA300mAOFF
Operating Modes
LiPo/LiIon/LiFe/LiHV
BALANCE, CHARGE, DISCHARGE, FAST CHG, STORAGE
NiCd/NiMH
CHARGE, AUTO CHG, CYCLE (Chg→Dischg, Dischg→Chg), Repeak (13 times), Discharge
Pb
Charge, Discharge
Charge Voltage
LiPo
4.184.25V/cell
LiIon
4.084.2V/cell
LiFe
3.583.7V/cell
LiHV
4.254.35V/cell
NiMH/NiCd
Delta peak detection
Pb
2.4 V/cell
LiPo/LiIon/LiFe/LiHV
(STORAGE mode)
3.80 V / 3.70 V / 3.30 V / 3.90 V
(per cell)
Peak detection
NiMH/NiCd
515 mV/cell (Default: 4 mV/cell)
Interval time between cycles
NiMH/NiCd (CYCLE)
160 minute(s)
Charge Time Cutoff
1720 minute(s), OFF (Default: 120 minutes)
Capacity Cutoff
10050000 mAh, OFF (Default: 5000 mAh)
Memory Profiles
Maximum of 10 profiles for charge/discharge
Battery Voltage Measurement
Available for LiPo/LiIon/LiFe/LiHV
Reverse Protection
(Output)
Standard equipped
Internal Resistance Measurement
Use of main and balance ports
USB
PC connection and firmware updates
USB Charging
5V 2.1A (±5%)
DC Input Voltage Protection
Low Voltage Alarm
1011V
High Voltage Alarm
1819V
Charge Power
AC/DC Input
50W (±10%)
40W when USB output used
Discharge Power
10W
Cooling Method
Air-cooled by internal fan
Operating Environment
Temperature: 040       Humidity:080%
Storage Environment
Temperature: 1060     Humidity: 2070%
Display
128 x 64 LCD with backlight
Weight
552 g
Dimensions
150 mm(length) × 145 mm(width) × 80 mm(height)